Practical guide

Corrective action in quality management: process, plan and examples

Corrective action in quality management: how it differs from correction, the process step by step, supplier corrective action and a tracking log.

Written by , Head of Quality (AS/EN 9100)

Updated:

Grounded in practiceWritten for real quality work
Ready to applyUse examples, templates, and clear steps
Useful next stepsConnected to relevant tools and guides

A corrective action removes the cause of a non-conformity so that it does not happen again. That is what distinguishes it from a correction, which only fixes the problem at hand. Sorting out the bad parts is a correction; changing the process so that bad parts are no longer made is a corrective action.

This page explains corrective action in the sense of ISO 9001 and related standards, with a focus on suppliers. (It is not about corrective action in HR, such as disciplinary letters to employees.)

Correction, corrective action, preventive action

Correction Corrective action Preventive action
Acts on The nonconforming product The cause of a non-conformity that occurred The cause of a potential non-conformity
Example Rework or scrap 40 bad parts Define a tool-life limit so the tool no longer wears out Apply the tool-life limit to all similar machines
Time Immediately After root cause analysis Proactively

CAPA (corrective and preventive action) is the combined term used mostly in medical devices and pharma. ISO 9001:2015 no longer has a separate “preventive action” clause; prevention is handled through risk-based thinking, but corrective action remains a core requirement (clause 10.2).

The corrective action process

Step What to do Output
1. React Contain and correct: stop, sort, block, inform Containment actions with owner and date
2. Analyse Find the root cause of occurrence and of non-detection Verified root causes (5 Why, Ishikawa)
3. Check for similar cases Could the same cause exist elsewhere? List of affected products and processes
4. Plan the action One action per root cause, with owner, due date and how effectiveness will be checked Corrective action plan
5. Implement Carry out the actions Evidence of implementation
6. Verify effectiveness Prove with data that the problem does not recur Effectiveness record
7. Update the system Risks, FMEA, control plan, instructions, training Updated documents

These steps are the same as in an 8D report, which is simply a structured format for them. For complex or customer-relevant problems, use the 8D; for simple, internal ones, a short corrective action record is enough.

Supplier corrective action

When the cause lies with a supplier, the supplier has to take the corrective action, and you have to make sure it is effective:

  1. Document the non-conformance in a non-conformance report (NCR).
  2. Send a supplier corrective action request (SCAR) with deadlines for containment, root cause and the full answer.
  3. The supplier answers with an 8D report; you can give them the free 8D report template.
  4. Review the answer critically, accept or reject it, and verify effectiveness on the next deliveries.
  5. Record the outcome in the supplier’s evaluation: severity, on-time closure and the quality of the 8D.

The whole flow, including deadlines and escalation, is described in supplier complaint management.

Example: a corrective action plan

Root cause Action Owner Due Effectiveness check
Occurrence: no tool-life limit for the deburring tool Tool change every 2,000 parts via the machine counter Process engineer 18 Oct 3 consecutive lots without burrs
Non-detection: burrs not part of the inspection plan Visual check for burrs added to the control plan, 1 part per hour Quality engineer 18 Oct Audit of inspection records after 4 weeks
Similar risk on other machines Tool-life limits for all deburring tools on machines 1–6 Production manager 15 Nov Check during the next process audit

Corrective action log

Track every corrective action in one log, whether it is a spreadsheet or software. Useful columns:

  • ID, date opened, source (customer complaint, supplier, internal, audit)
  • Product or process, supplier if applicable
  • Description of the non-conformity, severity
  • Root cause
  • Action(s), owner, due date
  • Status, date implemented
  • Effectiveness check: method, date, result
  • Date closed, closed by

Review the log regularly: overdue actions, repeated root causes, and suppliers with many open actions. A long list of “open, overdue” items is one of the most common audit findings.

What auditors look for

  • Is there a root cause, or only a description of the problem?
  • Does the action address that cause, or is it “retrain the operator” by default?
  • Was effectiveness verified with evidence, not just “action implemented”?
  • Were risks and documents updated where needed (clause 10.2.1 e–f)?
  • Are corrective actions closed on time, and is the backlog under control?

In medical devices, CAPA has long been a focus of FDA inspections; since the FDA’s quality management system regulation took effect in February 2026, the requirements are those of ISO 13485 (clauses 8.5.2 and 8.5.3), with FDA-specific additions.

FAQ

What is the difference between correction and corrective action?

A correction fixes the nonconforming product (rework, scrap, sort). A corrective action removes the cause, so the non-conformity does not happen again.

When is a corrective action required?

ISO 9001 requires you to evaluate the need for action whenever a non-conformity occurs. Not every minor deviation needs a full root cause analysis; decide by severity and whether the problem has occurred before.

How do you verify the effectiveness of a corrective action?

With data collected after implementation: for example several consecutive lots without the defect, no recurrence within a defined period, or improved capability values. Define the method when you plan the action.